Intrinsically Safe Speed Sensors

Motion Sensors intrinsically safe sensors are certified for use in both North America and Europe to the most stringent requirements. These speed sensors are certified intrinsically safe to CSA (with NRTL/C), ATEX (2014/34/EU), and IECEx (IEC 60079-0:2011 and IEC 60079-11:2011).

CUSTOM MODELS

In addition to our standard models, Intrinsically Safe speed sensors are available in custom lengths, diameters, configurations, and mounting threads. Custom operating specifications (output options, etc.) are available, as well as options such as pigtail leads or NPT threading. See additional sensor customization options.

Intrinsically Safe RF Sensors

Intrinsic safety has become an increasingly popular approach for handling sensing requirements in hazardous locations. These sensors are intrinsically safe versions of Motion Sensors Hermetically Sealed VR Sensors or Epoxy Encapsulated VR Sensors.

These sensors are certified intrinsically safe to:

  • CSA (with NRTL/C) for
    Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
    Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III

  • ATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2

  • IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2

Type
Variable reluctance (VR) or inductive type

Warranty
Unconditional one (1) year warranty if used within specifications

Physical Features

  • Body material: 300 series stainless steel (locknut included)
  • Encapsulation: hermetically sealed, heli-arc welded construction or epoxy encapsulation
  • Magnet that resists demagnetization
  • Focusing tip (pole piece) which allows greater air gap with no signal loss
  • IR leakage: 100 Mohms @ 100 VDC min.
  • High signal output
  • High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
 

Entity Parameters

  • Group IIC:
    - Vmax/Ui = 30 VDC
    - Imax/Ii = 300 mA
    - Pi = 0.75 W
    - Ci/Ci = 0 uF
    - Li/Li = 0 mH

Approvals

  • Intrinsic safety to CSA (with NRTL/C) for Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
  • LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC or IIB T6 to T3 Ga
  • IECEx for Ex ia IIC or IIB T6 to T3 Ga

Ambient Temperature

-50°C to 175°C

RF Standard 5/8x18 Thread

RF Standard 11/16x24 Thread

Hazardous Location: Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; and Class III)

MODEL NUMBERTYPEMOUNTING THREAD (A)THREAD LENGTH (B)OVERALL LENGTH (C)TIP (Length/Dia.) (D)RESISTANCE (Ohms)INDUCTANCE (Henry)GAUSS STRENGTHINTERCONNECTIONTEMPERATURE RANGE
PC45-46Value5/8x181.432.656.15/.187150Li/Li=0mH1200MIL-C-5015 Connector-50˚C to +120˚C
PC45-30Value5/8x181.432.656.20/.1061200Li/Li=0mH1000MIL-C-5015 Connector-50˚C to +120˚C
PC45-9Premium5/8x18.8752.685.31/.1001700Li/Li=0mH325MIL-C-5015 Connector-50˚C to +175˚C
PC45-7Premium5/8x18.8752.685.31/.1001200Li/Li=0mH810MIL-C-5015 Connector-50˚C to +175˚C
PC45-5Premium11/16x24.5632.685.70/.1251380Li/Li=0mH350MIL-C-5015 Connector-50˚C to +175˚C
PC45-1Premium11/16x24.5632.685.70/.1251800Li/Li=0mH850MIL-C-5015 Connector-50˚C to +175˚C
PC45-47Premium11/16x241.252.685Flush1380Li/Li=0mH350MIL-C-5015 Connector-50˚C to +175˚C
PC45-48Premium11/16x241.252.685Flush1800Li/Li=0mH850MIL-C-5015 Connector-50˚C to +175˚C

NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A

Intrinsically Safe VR Sensors

Intrinsic safety has become an increasingly popular approach for handling sensing requirements in hazardous locations. These sensors are intrinsically safe versions of Motion Sensors Hermetically Sealed VR Sensors or Epoxy Encapsulated VR Sensors.

These sensors are certified intrinsically safe to:

  • CSA (with NRTL/C) for
    Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
    Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III

  • ATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2

  • IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2

INSTALLATION CONSIDERATIONS

Type
Variable reluctance (VR) or inductive type

Warranty

Unconditional one (1) year warranty if used within specifications

Physical Features


  • Body material: 300 series stainless steel (locknut included)
  • Encapsulation: hermetically sealed, heli-arc welded construction or epoxy encapsulation
  • Magnet that resists demagnetization
Focusing tip (pole piece) which allows greater air gap with no signal loss
  • 
IR leakage: 100 Mohms @ 100 VDC min.
High signal output
  • High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
  • Interconnection Options
Two (2) pin gold plated glass sealed connector (mates with: MS3106-10SL-4S)
  • Pigtail with wires or cable
  • NPT threaded body with wire or cable pigtail for explosion proof environments

Entity Parameters


  • Group IIC:
    - Vmax/Ui = 30 VDC
    - 
Imax/Ii = 300 mA
    - 
Pi = 0.75 W
    - 
Ci/Ci = 0 uF
    - 
Li/Li = 0 mH

Approvals

  • 
Intrinsic safety to CSA (with NRTL/C) for Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
  • LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC or IIB T6 to T3 Ga
  • 
IECEx for Ex ia IIC or IIB T6 to T3 Ga

Ambient Temperature
-50°C to 175°C

Hazardous Location: Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; and Class III)

MODEL NUMBERTYPEMOUNTING THREAD (A)THREAD LENGTH (B)OVERALL LENGTH (C)TIP (Length/Dia.) (D)RESISTANCE (Ohms)INDUCTANCE (Henry)GAUSS STRENGTHINTERCONNECTIONTEMPERATURE RANGE
PC45-46Value5/8x181.432.656.15/.187150Li/Li=0mH1200MIL-C-5015 Connector-50˚C to +120˚C
PC45-30Value5/8x181.432.656.20/.1061200Li/Li=0mH1000MIL-C-5015 Connector-50˚C to +120˚C
PC45-9Premium5/8x18.8752.685.31/.1001700Li/Li=0mH325MIL-C-5015 Connector-50˚C to +175˚C
PC45-7Premium5/8x18.8752.685.31/.1001200Li/Li=0mH810MIL-C-5015 Connector-50˚C to +175˚C
PC45-5Premium11/16x24.5632.685.70/.1251380Li/Li=0mH350MIL-C-5015 Connector-50˚C to +175˚C
PC45-1Premium11/16x24.5632.685.70/.1251800Li/Li=0mH850MIL-C-5015 Connector-50˚C to +175˚C
PC45-47Premium11/16x241.252.685Flush1380Li/Li=0mH350MIL-C-5015 Connector-50˚C to +175˚C
PC45-48Premium11/16x241.252.685Flush1800Li/Li=0mH850MIL-C-5015 Connector-50˚C to +175˚C

NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A

Amplified Intrinsically Safe Sensors

Intrinsically Safe Digi-pulse sensors feature the same high-quality construction and materials as our standard Digi-Pulse models. They are certified by CSA (with NRTL/C) and LCIE to ATEX (2014/34/EU) and IECEx.

These sensors are certified intrinsically safe to:

  • CSA (with NRTL/C) for
    Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
    Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III

  • ATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2

  • IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2

EC DECLARATION OF CONFORMITY AND INSTALLATION CONSIDERATIONS

Type
Magnetic (Inductive or Variable Reluctance)

Physical Features

  • Body material: 300 series stainless steel
  • Encapsulation: epoxy potting or hermetically sealed, welded construction
  • High Shock and Vibration resistance - MIL-STD-202G METHOD 214A, Test Condition H

Input Power

  • 13 to 30 VDC, 35 mA @24 VDC (Class I, Zone 0, IIC models)
  • 7.5 to 30 VDC, 10 mA @ < 10 VDC (Class I, Zone 0, IIA models)
  • Reverse polarity protected

Pulse Output Options

  • TTL/CMOS; fan-out of 5 TTL/CMOS loads
  • Open Collector

Entity Parameters

  • Group IIA:
    - Vmax/Ui = 30 VDC; Imax/Ii = 190 mA
    - Pi = 2.55 W; Ci/Ci = 0.0 uF; Li/Li = 0.50 mH
  • Group IIC:
    - Vmax/Ui = 30 VDC; Imax/Ii = 200 mA
    - Pi = 0.75 W; Ci/Ci = 0.0 uF; Li/Li = 0.50 mH

Interconnection Options

  • Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request.
  • Pigtail with wires or cable
  • NPT threaded body with wire or cable pigtail for explosion proof environments

Ambient Temperature

  • CSA Certified Group IIC:
    - Temperature Code T2: -40°C to 125°C
    - Temperature Code T4: -40°C to 51°C
  • CSA Certified Group IIA:
    - Temperature Code T2: -40°C to 100°C
    - Temperature Code T4: -40°C to 51°C
  • ATEX and IECEx Certified Group IIC and IIA:
    - Temperature Code T2: -40°C to 125°C
    - Temperature Code T4: -40°C to 51°C

Pin/Pigtail Connections

  • Pin A (Red): Input Power (+)
  • Pin B (Black): Common (-)
  • Pin C (White): Pulse Output (+)

Airgap
Up to 0.140" dependent on target geometry and sensor construction

Approvals
Intrinsic Safety to CSA (with NRTL/C) for:

  • Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
  • Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III
  • LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC T4; Ex ia IIC T2; Ex ia IIA T4; Ex ia IIA T2
    IECEx for Ex ia IIC T4; Ex ia IIC T2; Ex ia
  • IIA T4; Ex ia IIA T2
  • CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments

Warranty
Unconditional one (1) year warranty if used within specifications

TABLES 1 & 2

Hazardous Location: Class I, Zone 0, IIC; Class I, Div. I, Group A, B, C, D and Class II, Div. I, Group G, Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class II, Div. 1, Group E, F, G, Class III)

Table 1: VR Intrinsically Safe Digi-Pulse Sensors

MODEL NUMBERMOUNTING THREAD (A)THREAD LENGTH (B)OVERALL LENGTH (C)TIP (Length/Dia.) (D)OUTPUT (Pulse Range)
DMX-002-15/8x18.8754.5.031/.100Open Collector
DMX-002-25/8x18.8754.5.031/.1000-5 VDC
DMX-001-15/8x18.8754.5.075/.105Open Collector
DMX-001-211/16x24.8754.5.075/.1050-5 VDC

Table 2: RF Intrinsically Safe Digi-Pulse Sensors

MODEL NUMBERMOUNTING THREAD (A)THREAD LENGTH (B)OVERALL LENGTH (C)TIP (Length/Dia.) (D)OUTPUT (Pulse Range)
DRX-021-15/8x18.8754.5Flush FrontOpen Collector
DRX-002-25/8x18.8754.5Flush Front0-5 VDC
DRX-001-111/16x24.8754.5Flush FrontOpen Collector
DRX-001-211/16x24.8754.5Flush Front0-5 VDC

TABLES 3 & 4

Hazardous Location: Class I, Zone 0, IIA; Class I, Div. I, Group D and Class II, Div. I, Group G, Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class II, Div. 1, Group E,F,G, Class III)

Table 3: VR Intrinsically Safe Digi-Pulse Sensors

MODEL NUMBERMOUNTING THREAD (A)THREAD LENGTH (B)OVERALL LENGTH (C)TIP (Length/Dia.) (D)OUTPUT (Pulse Range)
DMX-002-35/8x18.8754.5.031/.100Open Collector
DMX-002-45/8x18.8754.5.031/.1000-5 VDC
DMX-001-311/16x24.8754.5.075/.105Open Collector
DMX-001-411/16x24.8754.5.075/.1050-5 VDC

Table 4: RF Intrinsically Safe Digi-Pulse Sensors

MODEL NUMBERMOUNTING THREAD (A)THREAD LENGTH (B)OVERALL LENGTH (C)TIP (Length/Dia.) (D)OUTPUT (Pulse Range)
DRX-004-35/8x18.8754.7Flush FrontOpen Collector
DRX-002-45/8x18.8754.7Flush Front0-5 VDC
DRX-003-311/16x24.8754.7Flush FrontOpen Collector
DRX-001-411/16x24.8754.7Flush Front0-5 VDC

NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A

Intrinsically Safe Hall Effect Speed Sensors

Our Intrinsically Safe Hall Effect sensors feature the same high-quality construction and materials as our standard Hall Effect speed sensors. They are designed and developed for each specific customer application. These sensors are certified to CSA (with NRTL/C), LCIE to ATEX (2014/34/EU) and IECEx for hazardous locations listed below.

These sensors are certified intrinsically safe to:

  • CSA (with NRTL/C) for
    Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
    Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III

  • ATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2

  • IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2

EC DECLARATION OF CONFORMITY AND INSTALLATION CONSIDERATIONS

Input Power
  • 4.7 to 24 VDC regulated, 15 mA maximum @ no load
  • Reverse polarity protected

Pulse Output Options

  • TTL/CMOS (Standard); fanout of 5 TTL/CMOS loads\
  • Open collector
  • Supply tracking: logic 0: 0.4 VDC
  • logic 1: (VS-0.2)xRL/(RL+2200)
Airgap
Up to 0.100" dependent on target geometry and sensor construction
Interconnection Options
  • Magnet that resists demagnetization
  • Focusing tip
  • Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request
  • Pigtail with wires or cable
  • NPT threaded body with wire or cable pigtail for explosion proof environments
Warranty
Unconditional one (1) year warranty if used within specifications
Pin Connections
  • Pin A (Red): Input Power (+)
  • Pin B (White): Pulse Output (+)
  • Pin C (Black): Common (-)
Physical Features
  • Operating temperature:
    -40°C to +125°C with connector
    -40°C to +105°C with pigtail

NOTE: units that operate up to 150°C
are also available

  • Storage temperature:
    -40°C to +150°C with connector
    -40°C to +105°C with pigtail
  • Body material: 300 series stainless steel
  • Encapsulation: epoxy potting or hermetically sealed, welded construction
  • High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
Orientation
Alignment of the sensor to target rotation is required for optimal performance, ensuring proper orientation of the hall effect element to the magnetic field
Approvals
CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments

TYPEOUTPUTPART NUMBERHOUSINGCONNECTION TYPE
Open ConnectorSupply TrackingHD-116Flange MountConnector
Open ConnectorSupply TrackingHD-116Flange MountCable
Open ConnectorSupply TrackingHD-1185/8-18 ThreadCable
Open Collector5VHD-119Flange MountConnector
Open Collector5VHD-120Flange MountCable
Open Collector5VHD-1215/8-18 ThreadCable
Open CollectorIsolated, Supply TrackingHD-122Flange MountConnector
Open CollectorIsolated, Supply TrackingHD-122Flange MountCable
Open CollectorIsolated, Supply TrackingHD-1225/8-18 ThreadCable
Open CollectorIsolated, 5VHD-125Flange MountConnector
Open CollectorIsolated, 5VHD-126Flange MountCable
Open CollectorIsolated, 5VHD-125/8-18 ThreadCable
Open Collector5V, DirectionHD-131Flange MountConnector
Open Collector5V, DirectionHD-132Flange MountCable
Open Collector5V, DirectionHD-1335/8-18 ThreadCable
Open CollectorNoneHD-67Flange MountConnector
Open CollectorNoneHD-134Flange MountCable
Open CollectorNoneHD-1355/8-18 ThreadCable
Open CollectorDirectionHD-136Flange MountConnector
Open CollectorDirectionHD-137Flange MountCable
Open CollectorDirectionHD-1385/8-18 ThreadCable
Push/PullSupply TrackingHD-139Flange MountConnector
Push/PullSupply TrackingHD-140Flange MountCable
Push/PullSupply TrackingHD-1415/8-18 ThreadCable
Push/Pull5VHD-142Flange MountConnector
Push/Pull5VHD-143Flange MountCable
Push/Pull5VHD-1445/8-18 ThreadCable
Push/PullDifferential, Supply TrackingHD-145Flange MountConnector
Push/PullDifferential, Supply TrackingHD-146Flange MountCable
Push/PullDifferential, Supply TrackingHD-1475/8-18 ThreadCable
Push/PullDifferential, 5VHD-148Flange MountConnector
Push/PullDifferential, 5VHD-149Flange MountCable
Push/PullDifferential, 5VHD-1505/8-18 ThreadCable
Push/PullSupply Tracking, DirectionHD-151Flange MountConnector
Push/PullSupply Tracking, DirectionHD-152Flange MountCable
Push/PullSupply Tracking, DirectionHD-1535/8-18 ThreadCable
Push/Pull5V, DirectionHD-154Flange MountConnector
Push/Pull5V, DirectionHD-155Flange MountCable
Push/Pull5V, DirectionHD-1565/8-18 ThreadCable
Push/PullIsolated, Supply TrackingHD-157Flange MountConnector
Push/PullIsolated, Supply TrackingHD-158Flange MountCable
Push/PullIsolated, Supply TrackingHD-1595/8-18 ThreadCable

NOTES:

Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A

Intrinsically Safe Pre-Amplifiers

Motion Sensors PMX (variable reluctance) and PRX (RF) intrinsically safe preamplifiers offer features similar to our PA1001A preamplifiers / signal conditioners and can be used in hazardous environments with intrinsically safe Variable Reluctance VR or RF sensors (e.g., PC45-X or RF10-X, respectively).

These sensors are certified intrinsically safe to:

  • CSA (with NRTL/C) for
    Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
    Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III

  • ATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2

  • IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2

Product Specifications

Unlike our PA1001A preamplifiers, pulse outputs are factory installed and must be indicated when ordering. These preamplifiers are certified to CSA (with NRTL/C) and LCIE to ATEX (2014/34/EU) and IECEx

 

Input Power

  • 13 to 30 VDC, 35 mA @ 24VDC (Class I, Zone 0, IIC models)
  • 7.5 to 30 VDC, 10 mA @ < 10VDC (Class I, Zone 0, IIA models)
    Reverse polarity protected

RF Sensor Input

  • Modulation carrier frequency: 20 KHz
  • Input frequency: 2 Hz to 5 KHz, adjustable trigger level
  • Carrier adjustment: to allow precise tuning of carrier signal to physical environment (e.g., air gap, wall thickness)
  • Max. air gap: 0.160" (dependent on target geometry and construction)
  • Preferred coil inductance: 1.0 mH +/- 10%
  • Max. distance from sensor to preamp: 100'

VR Sensor Input

  • Input protected, RF and band pass filtered
  • Input frequency: 10 Hz to 10 KHz, adjustable trigger level
  • Trigger sensitivity: 10 mV RMS min. (note: at 10 mV frequency range 10 Hz to 3 KHz)
  • Input impedance: 40K ohms (nominal)
  • Max. input signal: 60 volts RMS
  • Max. distance from sensor to preamp: 100'

Pulse Output Options

  • All output options must be factory installed
  • Open Collector
  • TTL/CMOS (standard) fanout of 5 TTL/CMOS loads

Interconnection Options

  • Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request.
  • Pigtail with wires or cables.
  • NPT threaded body with wire or cable pigtail for explosion proof environments.

Physical Dimensions

  • Board diameter: 2.75"
  • Center mounting holes: 2" and 2.5"

Ambient Temperature

  • CSA Certified Group IIC:
    - Temperature Code T2: -40°C to 125°C
    - Temperature Code T4: -40°C to 51°C
  • CSA Certified Group IIA:
    - Temperature Code T2: -40°C to 100°C
    - Temperature Code T4: -40°C to 51°C
  • ATEX and IECEx Certified Group IIC and IIA:
    - Temperature Code T2: -40°C to 125°C
    - Temperature Code T4: -40°C to 51°C

Enclosures

  • Unit is intended for mounting in a conduit box. Enclosure is not required (unless using in Class II and III locations in which must be enclosed in an approved Class II/III enclosure) but recommended to protect unit from moisture, dirt, etc.
  • Optional explosion proof box available upon request

Entity Parameters

  • Group IIC
    To Barrier:
    - Vmax/Ui = 30 VDC, Imax/Ii = 200 mA
    - Pi = 0.75 W; Ci/Ci = 0.0uF, Li/Li = 0.50 mH
    To Sensor:
    - Voc/Uo = 5.9 VDC, Isc/Io = 64 mA
    - Ca/Co = 1 uF, La/Li = 3.5 mH
  • Group IIA
    To Barrier:
    - Vmax/Ui = 30 VDC, Imax/Ii = 190 mA - Pi = 2.55 W; Ci/Ci = 0.0uF, Li/Li = 0.50 mH
    To Sensor:
    - Voc/Uo = 10.5 VDC, Isc/Io = 190 mA
    - Ca/Co = 4 uF, La/Li = 1.5 mH
  • Approvals
    Intrinsically safe to CSA (with NRTL/C) for:
  • Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
  • Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III
  • LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC T4; Ex ia IIC T2; Ex ia IIA T4; Ex ia IIA T2
  • IECEx for Ex ia IIC T4; Ex ia IIC T2; Ex ia
  • IIA T4; Ex ia IIA T2
  • CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments

Warranty
Unconditional one (1) year warranty if used within specifications

STANDARD MODELS

Hazardous location: Class I, Zone 0, Group IIC and Class 1, Div. 1 Group A,B,C,D

MODEL NUMBERDESCRIPTIONOUTPUT (Pulse Range)ENCLOSURE COVER TYPE
PMX-001-1For Use With VR Sensor5/8x181.43
PMX-001-2For Use With VR Sensor5/8x181.43
PRX-002-1For Use With RF Sensor5/8x18.875
PRX-002-2For Use With RF Sensor5/8x18.875

Hazardous location: Class 1, Zone 0 Group IIA and Class 1, Div. 1, Group D

MODEL NUMBERDESCRIPTIONOUTPUT (Pulse Range)ENCLOSURE COVER TYPE
PMX-001-3For Use With VR Sensor5/8x181.43
PMX-001-4For Use With VR Sensor5/8x181.43
PRX-002-3For Use With RF Sensor5/8x18.875