- info@motionsensors.com
- Monday - Thursday: 8AM to 5PM EST
- 252-331-2080
Intrinsically Safe Speed Sensors
Motion Sensors intrinsically safe sensors are certified for use in both North America and Europe to the most stringent requirements. These speed sensors are certified intrinsically safe to CSA (with NRTL/C), ATEX (2014/34/EU), and IECEx (IEC 60079-0:2011 and IEC 60079-11:2011).
CUSTOM MODELS
In addition to our standard models, Intrinsically Safe speed sensors are available in custom lengths, diameters, configurations, and mounting threads. Custom operating specifications (output options, etc.) are available, as well as options such as pigtail leads or NPT threading. See additional sensor customization options.
Intrinsically Safe RF Sensors
Intrinsic safety has become an increasingly popular approach for handling sensing requirements in hazardous locations. These sensors are intrinsically safe versions of Motion Sensors Hermetically Sealed VR Sensors or Epoxy Encapsulated VR Sensors.
These sensors are certified intrinsically safe to:
CSA (with NRTL/C) for
Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class IIIATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2
IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2
- Features & Specifications
- Standard Models
Type
Variable reluctance (VR) or inductive type
Warranty
Unconditional one (1) year warranty if used within specifications
Physical Features
- Body material: 300 series stainless steel (locknut included)
- Encapsulation: hermetically sealed, heli-arc welded construction or epoxy encapsulation
- Magnet that resists demagnetization
- Focusing tip (pole piece) which allows greater air gap with no signal loss
- IR leakage: 100 Mohms @ 100 VDC min.
- High signal output
- High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
Entity Parameters
- Group IIC:
- Vmax/Ui = 30 VDC
- Imax/Ii = 300 mA
- Pi = 0.75 W
- Ci/Ci = 0 uF
- Li/Li = 0 mH
Approvals
- Intrinsic safety to CSA (with NRTL/C) for Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
- LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC or IIB T6 to T3 Ga
- IECEx for Ex ia IIC or IIB T6 to T3 Ga
Ambient Temperature
-50°C to 175°C
RF Standard 5/8x18 Thread | RF Standard 11/16x24 Thread |
Hazardous Location: Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; and Class III)
MODEL NUMBER | TYPE | MOUNTING THREAD (A) | THREAD LENGTH (B) | OVERALL LENGTH (C) | TIP (Length/Dia.) (D) | RESISTANCE (Ohms) | INDUCTANCE (Henry) | GAUSS STRENGTH | INTERCONNECTION | TEMPERATURE RANGE |
PC45-46 | Value | 5/8x18 | 1.43 | 2.656 | .15/.187 | 150 | Li/Li=0mH | 1200 | MIL-C-5015 Connector | -50˚C to +120˚C |
PC45-30 | Value | 5/8x18 | 1.43 | 2.656 | .20/.106 | 1200 | Li/Li=0mH | 1000 | MIL-C-5015 Connector | -50˚C to +120˚C |
PC45-9 | Premium | 5/8x18 | .875 | 2.685 | .31/.100 | 1700 | Li/Li=0mH | 325 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-7 | Premium | 5/8x18 | .875 | 2.685 | .31/.100 | 1200 | Li/Li=0mH | 810 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-5 | Premium | 11/16x24 | .563 | 2.685 | .70/.125 | 1380 | Li/Li=0mH | 350 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-1 | Premium | 11/16x24 | .563 | 2.685 | .70/.125 | 1800 | Li/Li=0mH | 850 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-47 | Premium | 11/16x24 | 1.25 | 2.685 | Flush | 1380 | Li/Li=0mH | 350 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-48 | Premium | 11/16x24 | 1.25 | 2.685 | Flush | 1800 | Li/Li=0mH | 850 | MIL-C-5015 Connector | -50˚C to +175˚C |
NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A
Intrinsically Safe VR Sensors
Intrinsic safety has become an increasingly popular approach for handling sensing requirements in hazardous locations. These sensors are intrinsically safe versions of Motion Sensors Hermetically Sealed VR Sensors or Epoxy Encapsulated VR Sensors.
These sensors are certified intrinsically safe to:
CSA (with NRTL/C) for
Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class IIIATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2
IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2
- Features & Specifications
- Standard Models
Type
Variable reluctance (VR) or inductive type
Warranty
Unconditional one (1) year warranty if used within specifications
Physical Features
- Body material: 300 series stainless steel (locknut included)
- Encapsulation: hermetically sealed, heli-arc welded construction or epoxy encapsulation
- Magnet that resists demagnetization Focusing tip (pole piece) which allows greater air gap with no signal loss
- IR leakage: 100 Mohms @ 100 VDC min. High signal output
- High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
- Interconnection Options Two (2) pin gold plated glass sealed connector (mates with: MS3106-10SL-4S)
- Pigtail with wires or cable
- NPT threaded body with wire or cable pigtail for explosion proof environments
Entity Parameters
- Group IIC:
- Vmax/Ui = 30 VDC
- Imax/Ii = 300 mA
- Pi = 0.75 W
- Ci/Ci = 0 uF
- Li/Li = 0 mH
Approvals
- Intrinsic safety to CSA (with NRTL/C) for Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
- LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC or IIB T6 to T3 Ga
- IECEx for Ex ia IIC or IIB T6 to T3 Ga
Ambient Temperature
-50°C to 175°C
![]() | ![]() |
Hazardous Location: Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class I, Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G; and Class III)
MODEL NUMBER | TYPE | MOUNTING THREAD (A) | THREAD LENGTH (B) | OVERALL LENGTH (C) | TIP (Length/Dia.) (D) | RESISTANCE (Ohms) | INDUCTANCE (Henry) | GAUSS STRENGTH | INTERCONNECTION | TEMPERATURE RANGE |
PC45-46 | Value | 5/8x18 | 1.43 | 2.656 | .15/.187 | 150 | Li/Li=0mH | 1200 | MIL-C-5015 Connector | -50˚C to +120˚C |
PC45-30 | Value | 5/8x18 | 1.43 | 2.656 | .20/.106 | 1200 | Li/Li=0mH | 1000 | MIL-C-5015 Connector | -50˚C to +120˚C |
PC45-9 | Premium | 5/8x18 | .875 | 2.685 | .31/.100 | 1700 | Li/Li=0mH | 325 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-7 | Premium | 5/8x18 | .875 | 2.685 | .31/.100 | 1200 | Li/Li=0mH | 810 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-5 | Premium | 11/16x24 | .563 | 2.685 | .70/.125 | 1380 | Li/Li=0mH | 350 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-1 | Premium | 11/16x24 | .563 | 2.685 | .70/.125 | 1800 | Li/Li=0mH | 850 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-47 | Premium | 11/16x24 | 1.25 | 2.685 | Flush | 1380 | Li/Li=0mH | 350 | MIL-C-5015 Connector | -50˚C to +175˚C |
PC45-48 | Premium | 11/16x24 | 1.25 | 2.685 | Flush | 1800 | Li/Li=0mH | 850 | MIL-C-5015 Connector | -50˚C to +175˚C |
NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A
Amplified Intrinsically Safe Sensors
Intrinsically Safe Digi-pulse sensors feature the same high-quality construction and materials as our standard Digi-Pulse models. They are certified by CSA (with NRTL/C) and LCIE to ATEX (2014/34/EU) and IECEx.
These sensors are certified intrinsically safe to:
CSA (with NRTL/C) for
Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class IIIATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2
IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2
EC DECLARATION OF CONFORMITY AND INSTALLATION CONSIDERATIONS
- Features & Specifications
- Standard Models
Type
Magnetic (Inductive or Variable Reluctance)
Physical Features
- Body material: 300 series stainless steel
- Encapsulation: epoxy potting or hermetically sealed, welded construction
- High Shock and Vibration resistance - MIL-STD-202G METHOD 214A, Test Condition H
Input Power
- 13 to 30 VDC, 35 mA @24 VDC (Class I, Zone 0, IIC models)
- 7.5 to 30 VDC, 10 mA @ < 10 VDC (Class I, Zone 0, IIA models)
- Reverse polarity protected
Pulse Output Options
- TTL/CMOS; fan-out of 5 TTL/CMOS loads
- Open Collector
Entity Parameters
- Group IIA:
- Vmax/Ui = 30 VDC; Imax/Ii = 190 mA
- Pi = 2.55 W; Ci/Ci = 0.0 uF; Li/Li = 0.50 mH - Group IIC:
- Vmax/Ui = 30 VDC; Imax/Ii = 200 mA
- Pi = 0.75 W; Ci/Ci = 0.0 uF; Li/Li = 0.50 mH
Interconnection Options
- Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request.
- Pigtail with wires or cable
- NPT threaded body with wire or cable pigtail for explosion proof environments
Ambient Temperature
- CSA Certified Group IIC:
- Temperature Code T2: -40°C to 125°C
- Temperature Code T4: -40°C to 51°C - CSA Certified Group IIA:
- Temperature Code T2: -40°C to 100°C
- Temperature Code T4: -40°C to 51°C - ATEX and IECEx Certified Group IIC and IIA:
- Temperature Code T2: -40°C to 125°C
- Temperature Code T4: -40°C to 51°C
Pin/Pigtail Connections
- Pin A (Red): Input Power (+)
- Pin B (Black): Common (-)
- Pin C (White): Pulse Output (+)
Airgap
Up to 0.140" dependent on target geometry and sensor construction
Approvals
Intrinsic Safety to CSA (with NRTL/C) for:
- Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
- Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III
- LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC T4; Ex ia IIC T2; Ex ia IIA T4; Ex ia IIA T2
IECEx for Ex ia IIC T4; Ex ia IIC T2; Ex ia - IIA T4; Ex ia IIA T2
- CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments
Warranty
Unconditional one (1) year warranty if used within specifications
![]() |
TABLES 1 & 2
Hazardous Location: Class I, Zone 0, IIC; Class I, Div. I, Group A, B, C, D and Class II, Div. I, Group G, Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class II, Div. 1, Group E, F, G, Class III)
Table 1: VR Intrinsically Safe Digi-Pulse Sensors
MODEL NUMBER | MOUNTING THREAD (A) | THREAD LENGTH (B) | OVERALL LENGTH (C) | TIP (Length/Dia.) (D) | OUTPUT (Pulse Range) |
DMX-002-1 | 5/8x18 | .875 | 4.5 | .031/.100 | Open Collector |
DMX-002-2 | 5/8x18 | .875 | 4.5 | .031/.100 | 0-5 VDC |
DMX-001-1 | 5/8x18 | .875 | 4.5 | .075/.105 | Open Collector |
DMX-001-2 | 11/16x24 | .875 | 4.5 | .075/.105 | 0-5 VDC |
Table 2: RF Intrinsically Safe Digi-Pulse Sensors
MODEL NUMBER | MOUNTING THREAD (A) | THREAD LENGTH (B) | OVERALL LENGTH (C) | TIP (Length/Dia.) (D) | OUTPUT (Pulse Range) |
DRX-021-1 | 5/8x18 | .875 | 4.5 | Flush Front | Open Collector |
DRX-002-2 | 5/8x18 | .875 | 4.5 | Flush Front | 0-5 VDC |
DRX-001-1 | 11/16x24 | .875 | 4.5 | Flush Front | Open Collector |
DRX-001-2 | 11/16x24 | .875 | 4.5 | Flush Front | 0-5 VDC |
TABLES 3 & 4
Hazardous Location: Class I, Zone 0, IIA; Class I, Div. I, Group D and Class II, Div. I, Group G, Class III and coal dust (If equipped with NPT/pigtail lead combinations, below units are also suitable for Class II, Div. 1, Group E,F,G, Class III)
Table 3: VR Intrinsically Safe Digi-Pulse Sensors
MODEL NUMBER | MOUNTING THREAD (A) | THREAD LENGTH (B) | OVERALL LENGTH (C) | TIP (Length/Dia.) (D) | OUTPUT (Pulse Range) |
DMX-002-3 | 5/8x18 | .875 | 4.5 | .031/.100 | Open Collector |
DMX-002-4 | 5/8x18 | .875 | 4.5 | .031/.100 | 0-5 VDC |
DMX-001-3 | 11/16x24 | .875 | 4.5 | .075/.105 | Open Collector |
DMX-001-4 | 11/16x24 | .875 | 4.5 | .075/.105 | 0-5 VDC |
Table 4: RF Intrinsically Safe Digi-Pulse Sensors
MODEL NUMBER | MOUNTING THREAD (A) | THREAD LENGTH (B) | OVERALL LENGTH (C) | TIP (Length/Dia.) (D) | OUTPUT (Pulse Range) |
DRX-004-3 | 5/8x18 | .875 | 4.7 | Flush Front | Open Collector |
DRX-002-4 | 5/8x18 | .875 | 4.7 | Flush Front | 0-5 VDC |
DRX-003-3 | 11/16x24 | .875 | 4.7 | Flush Front | Open Collector |
DRX-001-4 | 11/16x24 | .875 | 4.7 | Flush Front | 0-5 VDC |
NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A
Intrinsically Safe Hall Effect Speed Sensors
Our Intrinsically Safe Hall Effect sensors feature the same high-quality construction and materials as our standard Hall Effect speed sensors. They are designed and developed for each specific customer application. These sensors are certified to CSA (with NRTL/C), LCIE to ATEX (2014/34/EU) and IECEx for hazardous locations listed below.
These sensors are certified intrinsically safe to:
CSA (with NRTL/C) for
Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class IIIATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2
IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2
EC DECLARATION OF CONFORMITY AND INSTALLATION CONSIDERATIONS
- Features & Specifications
- Standard Models
Input Power
- 4.7 to 24 VDC regulated, 15 mA maximum @ no load
- Reverse polarity protected
Pulse Output Options
- TTL/CMOS (Standard); fanout of 5 TTL/CMOS loads\
- Open collector
- Supply tracking: logic 0: 0.4 VDC
- logic 1: (VS-0.2)xRL/(RL+2200)
Airgap
Up to 0.100" dependent on target geometry and sensor construction
Up to 0.100" dependent on target geometry and sensor construction
Interconnection Options
- Magnet that resists demagnetization
- Focusing tip
- Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request
- Pigtail with wires or cable
- NPT threaded body with wire or cable pigtail for explosion proof environments
Warranty
Unconditional one (1) year warranty if used within specifications
Unconditional one (1) year warranty if used within specifications
Pin Connections
- Pin A (Red): Input Power (+)
- Pin B (White): Pulse Output (+)
- Pin C (Black): Common (-)
Physical Features
- Operating temperature:
-40°C to +125°C with connector
-40°C to +105°C with pigtail
NOTE: units that operate up to 150°C
are also available
- Storage temperature:
-40°C to +150°C with connector
-40°C to +105°C with pigtail - Body material: 300 series stainless steel
- Encapsulation: epoxy potting or hermetically sealed, welded construction
- High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
Orientation
Alignment of the sensor to target rotation is required for optimal performance, ensuring proper orientation of the hall effect element to the magnetic field
Alignment of the sensor to target rotation is required for optimal performance, ensuring proper orientation of the hall effect element to the magnetic field
Approvals
CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments
CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments
TYPE | OUTPUT | PART NUMBER | HOUSING | CONNECTION TYPE |
Open Connector | Supply Tracking | HD-116 | Flange Mount | Connector |
Open Connector | Supply Tracking | HD-116 | Flange Mount | Cable |
Open Connector | Supply Tracking | HD-118 | 5/8-18 Thread | Cable |
Open Collector | 5V | HD-119 | Flange Mount | Connector |
Open Collector | 5V | HD-120 | Flange Mount | Cable |
Open Collector | 5V | HD-121 | 5/8-18 Thread | Cable |
Open Collector | Isolated, Supply Tracking | HD-122 | Flange Mount | Connector |
Open Collector | Isolated, Supply Tracking | HD-122 | Flange Mount | Cable |
Open Collector | Isolated, Supply Tracking | HD-122 | 5/8-18 Thread | Cable |
Open Collector | Isolated, 5V | HD-125 | Flange Mount | Connector |
Open Collector | Isolated, 5V | HD-126 | Flange Mount | Cable |
Open Collector | Isolated, 5V | HD-12 | 5/8-18 Thread | Cable |
Open Collector | 5V, Direction | HD-131 | Flange Mount | Connector |
Open Collector | 5V, Direction | HD-132 | Flange Mount | Cable |
Open Collector | 5V, Direction | HD-133 | 5/8-18 Thread | Cable |
Open Collector | None | HD-67 | Flange Mount | Connector |
Open Collector | None | HD-134 | Flange Mount | Cable |
Open Collector | None | HD-135 | 5/8-18 Thread | Cable |
Open Collector | Direction | HD-136 | Flange Mount | Connector |
Open Collector | Direction | HD-137 | Flange Mount | Cable |
Open Collector | Direction | HD-138 | 5/8-18 Thread | Cable |
Push/Pull | Supply Tracking | HD-139 | Flange Mount | Connector |
Push/Pull | Supply Tracking | HD-140 | Flange Mount | Cable |
Push/Pull | Supply Tracking | HD-141 | 5/8-18 Thread | Cable |
Push/Pull | 5V | HD-142 | Flange Mount | Connector |
Push/Pull | 5V | HD-143 | Flange Mount | Cable |
Push/Pull | 5V | HD-144 | 5/8-18 Thread | Cable |
Push/Pull | Differential, Supply Tracking | HD-145 | Flange Mount | Connector |
Push/Pull | Differential, Supply Tracking | HD-146 | Flange Mount | Cable |
Push/Pull | Differential, Supply Tracking | HD-147 | 5/8-18 Thread | Cable |
Push/Pull | Differential, 5V | HD-148 | Flange Mount | Connector |
Push/Pull | Differential, 5V | HD-149 | Flange Mount | Cable |
Push/Pull | Differential, 5V | HD-150 | 5/8-18 Thread | Cable |
Push/Pull | Supply Tracking, Direction | HD-151 | Flange Mount | Connector |
Push/Pull | Supply Tracking, Direction | HD-152 | Flange Mount | Cable |
Push/Pull | Supply Tracking, Direction | HD-153 | 5/8-18 Thread | Cable |
Push/Pull | 5V, Direction | HD-154 | Flange Mount | Connector |
Push/Pull | 5V, Direction | HD-155 | Flange Mount | Cable |
Push/Pull | 5V, Direction | HD-156 | 5/8-18 Thread | Cable |
Push/Pull | Isolated, Supply Tracking | HD-157 | Flange Mount | Connector |
Push/Pull | Isolated, Supply Tracking | HD-158 | Flange Mount | Cable |
Push/Pull | Isolated, Supply Tracking | HD-159 | 5/8-18 Thread | Cable |
NOTES:
Dimensions in inches
Specifications +/-10%
Mounting threads UNF-2A
Intrinsically Safe Pre-Amplifiers
Motion Sensors PMX (variable reluctance) and PRX (RF) intrinsically safe preamplifiers offer features similar to our PA1001A preamplifiers / signal conditioners and can be used in hazardous environments with intrinsically safe Variable Reluctance VR or RF sensors (e.g., PC45-X or RF10-X, respectively).
These sensors are certified intrinsically safe to:
CSA (with NRTL/C) for
Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class IIIATEX (2014/34/EU) for Ex II 1 G, Ex ia IIC T4 and T2, and Ex ia IIA T4 and T2
IECEx for Ex ia IIC T4 or T2; Ex ia IIA T4 or T2
Product Specifications
Unlike our PA1001A preamplifiers, pulse outputs are factory installed and must be indicated when ordering. These preamplifiers are certified to CSA (with NRTL/C) and LCIE to ATEX (2014/34/EU) and IECEx
- Features & Specifications
- Standard Models
Input Power
- 13 to 30 VDC, 35 mA @ 24VDC (Class I, Zone 0, IIC models)
- 7.5 to 30 VDC, 10 mA @ < 10VDC (Class I, Zone 0, IIA models)
Reverse polarity protected
RF Sensor Input
- Modulation carrier frequency: 20 KHz
- Input frequency: 2 Hz to 5 KHz, adjustable trigger level
- Carrier adjustment: to allow precise tuning of carrier signal to physical environment (e.g., air gap, wall thickness)
- Max. air gap: 0.160" (dependent on target geometry and construction)
- Preferred coil inductance: 1.0 mH +/- 10%
- Max. distance from sensor to preamp: 100'
VR Sensor Input
- Input protected, RF and band pass filtered
- Input frequency: 10 Hz to 10 KHz, adjustable trigger level
- Trigger sensitivity: 10 mV RMS min. (note: at 10 mV frequency range 10 Hz to 3 KHz)
- Input impedance: 40K ohms (nominal)
- Max. input signal: 60 volts RMS
- Max. distance from sensor to preamp: 100'
Pulse Output Options
- All output options must be factory installed
- Open Collector
- TTL/CMOS (standard) fanout of 5 TTL/CMOS loads
Interconnection Options
- Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request.
- Pigtail with wires or cables.
- NPT threaded body with wire or cable pigtail for explosion proof environments.
Physical Dimensions
- Board diameter: 2.75"
- Center mounting holes: 2" and 2.5"
Ambient Temperature
- CSA Certified Group IIC:
- Temperature Code T2: -40°C to 125°C
- Temperature Code T4: -40°C to 51°C - CSA Certified Group IIA:
- Temperature Code T2: -40°C to 100°C
- Temperature Code T4: -40°C to 51°C - ATEX and IECEx Certified Group IIC and IIA:
- Temperature Code T2: -40°C to 125°C
- Temperature Code T4: -40°C to 51°C
Enclosures
- Unit is intended for mounting in a conduit box. Enclosure is not required (unless using in Class II and III locations in which must be enclosed in an approved Class II/III enclosure) but recommended to protect unit from moisture, dirt, etc.
- Optional explosion proof box available upon request
Entity Parameters
- Group IIC
To Barrier:
- Vmax/Ui = 30 VDC, Imax/Ii = 200 mA
- Pi = 0.75 W; Ci/Ci = 0.0uF, Li/Li = 0.50 mH
To Sensor:
- Voc/Uo = 5.9 VDC, Isc/Io = 64 mA
- Ca/Co = 1 uF, La/Li = 3.5 mH - Group IIA
To Barrier:
- Vmax/Ui = 30 VDC, Imax/Ii = 190 mA - Pi = 2.55 W; Ci/Ci = 0.0uF, Li/Li = 0.50 mH
To Sensor:
- Voc/Uo = 10.5 VDC, Isc/Io = 190 mA
- Ca/Co = 4 uF, La/Li = 1.5 mH - Approvals
Intrinsically safe to CSA (with NRTL/C) for: - Ex ia IIC: Class I, Zone 0: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
- Ex ia IIA: Class I, Zone 0: Class I, Group D; Class II, Groups E, F, G; Class III
- LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC T4; Ex ia IIC T2; Ex ia IIA T4; Ex ia IIA T2
- IECEx for Ex ia IIC T4; Ex ia IIC T2; Ex ia
- IIA T4; Ex ia IIA T2
- CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments
Warranty
Unconditional one (1) year warranty if used within specifications
STANDARD MODELS
Hazardous location: Class I, Zone 0, Group IIC and Class 1, Div. 1 Group A,B,C,D
MODEL NUMBER | DESCRIPTION | OUTPUT (Pulse Range) | ENCLOSURE COVER TYPE |
PMX-001-1 | For Use With VR Sensor | 5/8x18 | 1.43 |
PMX-001-2 | For Use With VR Sensor | 5/8x18 | 1.43 |
PRX-002-1 | For Use With RF Sensor | 5/8x18 | .875 |
PRX-002-2 | For Use With RF Sensor | 5/8x18 | .875 |
Hazardous location: Class 1, Zone 0 Group IIA and Class 1, Div. 1, Group D
MODEL NUMBER | DESCRIPTION | OUTPUT (Pulse Range) | ENCLOSURE COVER TYPE |
PMX-001-3 | For Use With VR Sensor | 5/8x18 | 1.43 |
PMX-001-4 | For Use With VR Sensor | 5/8x18 | 1.43 |
PRX-002-3 | For Use With RF Sensor | 5/8x18 | .875 |
PRX-002-4 | For Use With RF Senso | 5/8x18 | .875 |