Intrinsic safety has
become an increasingly popular approach
for handling sensing requirements in
hazardous locations. These sensors are
intrinsically safe versions of Motion
Sensors (MSI)
Premium
or
Value
variable reluctance (VR) sensors. CSA
(with NRTL/C) and LCIE to ATEX (94/9/EC)
certify them. Intrinsically safe models
feature high quality construction and
materials.
In
addition to the models specified, MSI can make
custom Intrinsically Safe VR sensors in other
lengths, diameters, configurations, mounting threads
(e.g., metric) as well as with different operating
specifications and options like pigtail leads, NPT
threads for explosion proof applications, etc. to
satisfy special requirements. Our certifications
permit us to make intrinsically safe versions of almost
any MSI sensor, or to customize a sensor to suit a
particular application or customer need. The
customization process for Intrinsically Safe products at
MSI is straightforward, quick, offers more choice, and
is less costly than our competitors. Just tell us what
you want and we will provide a fully certified CUSTOM
INTRINSICALLY SAFE PRODUCT IN WEEKS, NOT MONTHS, made to
your specifications, even if you only need one piece!
This ability to provide rapid development of custom
certified product WITHOUT THE NORMAL CERTIFICATION COSTS
AND LEADTIMES is due to our unique "modular"
certification scheme with CSA and ATEX. Please contact
us to learn how Motion Sensors can provide a customized
Intrinsically Safe VR sensor for your
application.
Product Features &
Specifications
Type:
Variable
reluctance (VR) or inductive
type
Warranty:
Unconditional one (1) year warranty if
used within specifications
Physical Features:
Body material: 300 series stainless steel
(locknut included)
Encapsulation: hermetically sealed,
heli-arc welded construction (standard) or epoxy
encapsulation
Magnet that resists demagnetization
Focusing tip (pole piece) which allows
greater air gap with no signal loss
IR
leakage: 100 Mohms @ 100 VDC min.
High signal output
High Shock and Vibration resistance -
Impact: 15 G's (11 mS, 1/2 sine) min.;
Vibration: 20 G's at 2,000 Hz
min
NPT threaded body with wire or cable
pigtail for explosion proof
environments
Entity
Parameters:
Group IIC:
Vmax/Ui = 30 VDC
Imax/Ii = 300 mA Ci/Ci = 0
uF
Li/Li = 0 mH
Approvals:
Intrinsic safety to CSA (with NRTL/C) and
LCIE to ATEX (94/9/EC).
Temperature
Range:
-54°F to
346°F
(-65°C to
175°C)
Dimension Key -
Click on graphic to
view full size.
Hazardous Location: Class I, Div. I,
Group A,B,C,D; Class II, Div. I, Group E,F,G; Class III
and coal dust (If equipped with NPT/pigtail lead
combinations, below units are also suitable for Class I,
Div. I, Group A,B,C,D; Class II, Div. I, Group E,F,G;
and Class III)