Motion Sensors
(MSI) intrinsically safe Digi-pulse sensors feature the
same high quality construction and materials as our
standard Digi-Pulse
models. They are certified by CSA (with NRTL/C) and LCIE
to ATEX (94/9/EC) for Class I, Zone 0, IIC and II 1 G
EEx ia IIC T4, or Class I, Zone 0, IIA and II 1 G EEx ia
IIA T4 hazardous locations.
In addition to the models specified, MSI can make
custom intrinsically safe Digi-Pulse sensors in other
lengths, diameters, configurations, mounting threads
(e.g., metric) as well as with different operating
specifications and options like pigtail leads, NPT
threads for explosion proof applications, etc. to
satisfy special requirements. Our certifications permit
us to make intrinsically safe versions of almost any MSI
sensor, or to customize a sensor to suit a particular
application or customer need. The customization process
for Intrinsically Safe products at MSI is
straightforward, quick, offers more choice, and is less
costly than our competitors. Just tell us what you want
and we will provide a fully certified CUSTOM
INTRINSICALLY SAFE PRODUCT IN WEEKS, NOT MONTHS, made to
your specifications, even if you only need one piece!
This ability to provide rapid development of custom
certified product WITHOUT THE NORMAL CERTIFICATION COSTS
AND LEADTIMES is due to our unique "modular"
certification scheme with CSA and ATEX. If you do not
see a sensor that meets your needs please contact us to
learn how Motion Sensors can provide a customized
Intrinsically Safe Digi-Pulse sensor for your
application.
Features and
Specifications
Type:
Magnetic (Inductive
or Variable Reluctance)
Physical
Features:
Body material: 300 series stainless steel
Encapsulation: epoxy potting or
hermetically sealed, welded construction
High Shock and Vibration resistance -
Impact: 100 G's (6 mS, 1/2 sine) min.;
Vibration: 20 G's at 2,000 Hz
min
Input Power:
13 to 30 VDC, 35 mA @24 VDC (Class I,
Zone 0, IIC models)
7.5 to 30 VDC, 10 mA @ < 10
VDC (Class I, Zone 0, IIA models)
Reverse polarity
protected
Pulse Output
Options:
TTL/CMOS; fan-out of 5 TTL/CMOS loads
Open collector; maximum OFF
voltage 30 VDC, maximum ON current 0.40
A
Entity Parameters
Group IIA: Vmax/Ui = 30 VDC; Imax/Ii = 190
mA Ci/Ci = 0.0 uF; Li/Li = .50 mH
Group IIC:
Vmax/Ui = 30 VDC; Imax/Ii = 200
mA Ci/Ci = 0.0 uF; Li/Li = .50
mH
Ambient Temperature:
-20°C to 40°C
Interconnection Options
Three (3) pin
MIL-C-5015 type connector with gold plated pins;
mates with MS3106-10SL-3S; other connector types
upon request.
Pigtail with wires or cable
NPT threaded body with wire or
cable pigtail for explosion proof environments
Pin/Pigtail
Connections
Pin A (Red): Input Power (+)
Pin B (Black): Common (-)
Pin C (White): Pulse Output
(+)
Airgap
Up to
0.140" dependent on target geometry and sensor
construction
Approvals
Intrinsic Safety to CSA (with NRTL/C) and
LCIE to ATEX (94/9/EC)
CE compliant to
EMC Directive 89/336/EEC for use in residential,
commercial, light industrial and heavy
industrial
environments
Warranty
Unconditional one (1) year warranty if
used within
specifications
Dimension Key - Click on graphic to view full
size.
Tables
1 & 2 Hazardous Location: Class I, Zone 0, IIC;
Class I, Div. I, Group A,B,C,D and Class II, Div. I,
Group G, Class III and coal dust (If equipped
with NPT/pigtail lead combinations, below units are also
suitable for Class II, Div. 1, Group E,F,G, Class
III)
Table 1 VR
Intrinsically Safe Digi-Pulse
Sensors
Model Number
Mounting Thread
(A)
Thread Length (B)
Overall Length (C)
Tip (Length/Dia.) (D)
Output (Pulse
Range)
DMX-002-1
5/8x18
.875
4.5
.031/.100
open collector
DMX-002-2
5/8x18
.875
4.5
.031/.100
0-5 VDC
DMX-001-1
11/16x24
.875
4.5
.075/.105
open collector
DMX-001-2
11/16x24
.875
4.5
.075/.105
0-5 VDC
Table 2 RF Intrinsically Safe
Digi-Pulse Sensors
Model Number
Mounting Thread
(A)
Thread Length (B)
Overall Length (C)
Tip (Length/Dia.) (D)
Output (Pulse
Range)
DRX-002-1
5/8x18
.875
4.7
flush front
open collector
DRX-002-2
5/8x18
.875
4.7
flush front
0-5 VDC
DRX-001-1
11/16x24
.875
4.7
flush front
open collector
DRX-001-2
11/16x24
.875
4.7
flush front
0-5 VDC
Tables 3 & 4 Hazardous
Location: Class I, Zone 0, IIA; Class I, Div. I, Group D
and Class II, Div. I, Group G, Class III and coal
dust (If equipped with NPT/pigtail lead
combinations, below units are also suitable for Class
II, Div. 1, Group E,F,G, Class
III)